Aixton cable-Testing network cable steps

July 19, 2024
Latest company news about Aixton cable-Testing network cable steps

1

The details of making Category 6 finished network cables: First, the wires do not need to be straightened. If they are straightened, the wire joints will change. Although it is easy to operate, it still cannot pass the single test, and the core wire structure and the surface of the core wire material will be damaged.

2
When processing the crystal head, be sure to pay attention to not damaging the weak distance of the wire. If it is damaged, then the test parameters will be directly reduced.

3
When testing, it is very important to wind the wire, because when you wind the wire into a ball, it is not easy to pass. In the test standard or during construction, it is directly straightened for testing. So you should pay attention to these.

4
When testing, you must choose the right adapter, that is, two connectors. Generally, non-shielded ones should use non-shielded ones, and shielded ones should use shielded ones. This depends on the wire. In addition, the adapters are divided into near-end and far-end.

5
For example, this time the test is the cat6 utp patch test. Whether it is the adapter or the test item, this word must be displayed. In addition, do not choose ISO first, but must choose TIA, which is generally the North American standard.

6
Another test option is to select the number of meters you want. Usually the length is built-in. If it is not, choose a length that is longer than this.